Literature
- 2007
A methodology for TLD postal dosimetry audit of high-energy radiotherapy photon beams in non-reference conditions
IŻEWSKA, J. et al., A methodology for TLD postal dosimetry audit of high-energy radiotherapy photon beams in non-reference conditions, Radiotherapy and Oncology 84 1 (2007) 67.
- 2008
A new formalism for reference dosimetry of small and nonstandard fields
ALFONSO, R. et al., A new formalism for reference dosimetry of small and nonstandard fields, Med. Phys. 35 11 (2008) 5179.
- 2003
AAPM Online Only Report No. OR01 - Information Transfer from Beam Data Acquisition Systems. (2003)
MEEKS, S. et al., Information Transfer from Beam Data Acquisition Systems., AAPM (2003).
- 2005
AAPM Online Report No. OR03 - Assessment of Display Performance for Medical Imaging Systems. (2005)
SAMEI, E. et al., Assessment of display performance for medical imaging systems: Executive summary of AAPM TG18 report, Med. Phys. 32 4 (2005) 1205.
- 2001
AAPM protocol for 40–300 kV x‐ray beam dosimetry in radiotherapy and radiobiology
MA, C.-M. et al., AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology, Med. Phys. 28 6 (2001) 868.
- 1986
AAPM Report No. 017 - The Physical Aspects of Total and Half Body Photon Irradiation (1986)
DYK, J.V., GALVIN, J.M., GLASGOW, G.P., PODGORSAK, E.B., The Physical Aspects of Total and Half Body Photon Irradiation, AAPM (1986).
- 1987
AAPM Report No. 023 - Total Skin Electron Therapy: Technique and Dosimetry (1987)
KARZMARK, C.J. et al., Total Skin Electron Therapy: Technique and Dosimetry, AAPM (1987).
- 1992
AAPM Report No. 037 - Auger Electron Dosimetry (1992)
KEREIAKES, J.G., RAO, D.V., Auger electron dosimetry: Report of AAPM Nuclear Medicine Committee Task Group No. 6, Med. Phys. 19 6 (1992) 1359.
- 1994
AAPM Report No. 049 - Dosimetry of Auger-Electron-Emitting Radionuclides (1994)
HUMM, J.L., HOWELL, R.W., RAO, D.V., Dosimetry of Auger-electron-emitting radionuclides: Report No. 3 of AAPM Nuclear Medicine Task Group No. 6, Med. Phys. 21 12 (1994) 1901.
- 1995
AAPM Report No. 050 - Fetal Dose from Radiotherapy with Photon Beams (1995)
STOVALL, M. et al., Fetal Dose from Radiotherapy with Photon Beams, AAPM (1995).
- 1995
AAPM Report No. 054 - Stereotactic Radiosurgery (1995)
SCHELL, M.C. et al., Stereotactic Radiosurgery, AAPM (1995).
- 1998
AAPM Report No. 059 - Code of practice for brachytherapy physics: Report of the AAPM Radiation Therapy Committee Task Group No. 56 (1997)
NATH, R. et al., Code of practice for brachytherapy physics: Report of the AAPM Radiation Therapy Committee Task Group No. 56, Med. Phys. 24 10 (1997) 1557.
- 1998
AAPM Report No. 061 - High dose-rate brachytherapy treatment delivery: Report of the AAPM Radiation Therapy Committee Task Group No. 59 (1998)
KUBO, H.D., GLASGOW, G.P., PETHEL, T.D., THOMADSEN, B.R., WILLIAMSON, J.F., High dose-rate brachytherapy treatment delivery: Report of the AAPM Radiation Therapy Committee Task Group No. 59, Med. Phys. 25 4 (1998) 375.
- 1998
AAPM Report No. 063 - Radiochromic Film Dosimetry (1998)
NIROOMAND-RAD, A. et al., Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55, Med. Phys. 25 11 (1998) 2093.
- 1998
AAPM Report No. 065 - Real-Time B-Mode Ultrasound Quality Control Test Procedures (1998)
GOODSITT, M.M., CARSON, P.L., WITT, S., HYKES, D.L., KOFLER, J.M., Jr., Real-timeB-mode ultrasound quality control test procedures. Report of AAPM Ultrasound Task Group No. 1, Med. Phys. 25 8 (1998) 1385.
- 2001
AAPM Report No. 071 - A Primer for Radioimmunotherapy and Radionuclide Therapy (2001)
MACEY, D.J. et al., A Primer for Radioimmunotherapy and Radionuclide Therapy, AAPM (2001).
- 2001
AAPM Report No. 075 - Clinical use of electronic portal imaging: Report of AAPM Radiation Therapy Committee Task Group 58 (2001)
HERMAN, M.G. et al., Clinical use of electronic portal imaging: Report of AAPM Radiation Therapy Committee Task Group 58, Med. Phys. 28 5 (2001) 712.
- 2003
AAPM Report No. 081 - Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation (2003)
REFT, C. et al., Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63, Med. Phys. 30 6 (2003) 1162.
- 2003
AAPM Report No. 082 - Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee (2003)
EZZELL, G.A. et al., Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee, Med. Phys. 30 8 (2003) 2089.
- 2003
AAPM Report No. 083 - Quality assurance for computed-tomography simulators and the computed-tomography-simulation process: Report of the AAPM Radiation Therapy Committee Task Group No. 66 (2003)
MUTIC, S. et al., Quality assurance for computed-tomography simulators and the computed-tomography-simulation process: Report of the AAPM Radiation Therapy Committee Task Group No. 66, Med. Phys. 30 10 (2003) 2762.
- 1 of 8
- next ›