As compared with the conventional manufacture of apparatus, there are some essential differences due to the utilization of 950oC hot helium from a HTR, installation in a PCRV, prevention of major failures, and long lifetime. The following basic solutions result from these essential features: Metallic tubular heat exchanger with extremely high wall temperatures. Precautionary measures (in-service inspections). Fully qualified material. Comprehensive analyses of the strength and creep behaviour. Comprehensive qualification tests of the component. The above-mentioned constructive features and the respective solutions are discussed with the He/He intermediate heat exchanger (IHX) and the steam reformer (StR) used as examples