Fast Reactors and Accelerator Driven Systems Knowledge Base
Conference Article: Seismic behaviour of in air Monju core mock-up
Fontaine, B. (CEA Centre d'Etudes de Saclay, 91 - Gif-sur-Yvette (France))
Abstract
This paper, which presents the CASTEM 2000 calculations performed by CEA/DMT in the framework of IAEA CRP on the intercomparison of LMFBR Seismic Analysis Codes, is a complement of a previous study performed with revised data.
The calculations are related to the behaviour of two types of MONJU core mock-ups :
- single row layout with 29 assemblies
- hexagonal cluster layout with 37 assemblies
This study is limited to the analysis of tests performed in air.
view the full text of this article
(13 pages, format: PDF, size= 367kB)
key words: air; c codes; mockup; monju reactor; reactor cores; seismic effects; theoretical data
- Reference:
- Research co-ordination meeting on intercomparison of liquid metal fast reactor seismic analysis codes. Vienna (Austria). 26-28 Sep 1994
- International Atomic Energy Agency, Vienna (Austria)
- IAEA-TECDOC--829, pp:178-190