Weber, M.H. (Sulzer Brothers Ltd, Winterthur (Switzerland))Abstract
After a short review of the phenomenon of static instability also called excursive instability - an overview of those specific features of the THTR steam generator follows. which must be observed when taking actions to prevent flow instabilities. These features are in detail: restricted number of tube penetrations, tube arrangement within the helical bundle, downhill flow, part load conditions, temperature limits for the ferritic/austenitic material transition joint. Then the required stabilizing pressure drops and the means provided to produce these pressure drops are discussed: orifice in the single tube, fixed orifice in the system tube, adjustable orifice in the system tube.
view the full text of this article (4 pages, format: PDF, size= 531kB)
key words: Gas Cooled Reactor, Nuclear Technology
- Reference:
- Specialists' meeting on technology of steam generators for gas-cooled reactors Winterthur (Switzerland) 9-12 Mar 1987
- International Atomic Energy Agency, International Working Group on Gas-Cooled Reactors, Vienna (Austria)
- IWGGCR--15, pp:200-203
- International Atomic Energy Agency, International Working Group on Gas-Cooled Reactors, Vienna (Austria)