HTGR Knowledge Base

Conference Article: Dynamics of a Small Direct Cycle Pebble Bed HTR

E.C. Verkerk, A.I. van Heek NRG, P.O.Box 25, NL-1755 ZG Petten, The Netherlands

Abstract

The Dutch market for combined generation of heat and power indentifies a unit size of 40 MW thermal for the conceptual design of a nuclear congeneration plant. The ACACIA system provides 14 Mwe electricity combined with 17t/h of high temperature steam (220oC, 10 bar) with a pebble bed high temperature reactor directly coupled with a helium compressor and a helium turbine.
To come to quantitative statements abjout the ACACIA transient behaviour, a calculational coupling between the high temperature reactor core analysis code package Panthermic (Panther-Termic/Direkt) and the thermal hydraulical code RELAP5 for the energy conversion system has been made.
It appears that the maximum fuel temperatures are naot reached during a LOFI or LOCI with a halted mass flow rate, but for situations with a small mass flow rate, 1-0.5 percent. As such, a LOFI or LOCI does not represent the worst-case scenatio in terms of maximal fuel temperature.

view the full text of this article (9 pages, format: PDF, size= 104kB)


key words: Gas Cooled Reactor, Nuclear Technology
Reference:
IAEA Technical Committee Meeting on “Gas Turbine Power Conversion Systems for Modular HTGRs”, held from 14-16 November 2000 in Palo Alto, California
International Atomic Energy Agency, Vienna (Austria). Technical Working Group on Gas-Cooled Reactors
IAEA-TECDOC--1238, pp:78-86