Fast Reactors and Accelerator Driven Systems Knowledge Base
Conference Article: Detection of sodium/water reaction in a steam generator: Results of a 1995 benchmark test
Oriol, L. (CEA Centre d'Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (France))Abstract
The CEA analysis of the 1995 benchmark test has been focused on the location of the injections. Two techniques have been tested: the pulse timing technique, and the time-domain delay and sum beamforming technique. The two methods gave coherent locations of the injector even if there was a difference of 25% of the SGU height between the vertical locations. Prior to that analysis, the RMS values of the signals were calculated in different frequency bands. The results obtained in the 200-1000 Hz were used to draw a rough estimation of the beginnings of the injections in order to determine the parts of the records on which the location signal processing can be carried out.
view the full text of this article (13 pages, format: PDF, size= 512kB)
key words: Fast Neutron Spectrum Systems, Nuclear Technology
- Reference:
- Acoustic signal processing for the detection of sodium boiling or sodium-water reaction in LMFRs. Final report of a co-ordinated research programme 1990-1995
- International Atomic Energy Agency, Vienna (Austria)
- IAEA-TECDOC--946, pp:135-147
- International Atomic Energy Agency, Vienna (Austria)